Number: ACK110189U2000
Subject: NetWare 286 v2.15c Corrections and Fixes
Date: November, 1989
- - - - - - - - - - - - - - - - -
GENERAL
INFORMATION:
CORRECTIONS AND FIXES
The following are descriptions of problems in SFT and
Advanced NetWare 286 v2.15 revisions A and B. Each of these
problems has been corrected in the NetWare 286 2.15 rev. C
maintenance release.
Operating System Problems Corrected
o If eight or more file servers existed on an
internetwork using external bridges then it is possible
to lose every eighth server in the router table. The
symptom of this problem is a fully functional file
server which some users cannot log into. When they
attempted to log into that server they would receive
the response "unknown file server." This is corrected
o Copying files from a DOS partition to a NetWare
partition on a non- dedicated file server in a 80386
machine would cause the error "ABEND: Invalid task
state interrupt passed to kernel." This is fixed.
o If the non-dedicated operating system size was greater
than 512 KB, the system would crash with a General
Protection Interrupt (GPI). The non-dedicated operating
system would only load eight 64 KB segments. When an
operating system exceeded this limit, the last 64 KB
would not get loaded. The limit is increased to nine
64 KB segments (576 KB). This was as large as a
non-dedicated operating system can be in order to
reserve sufficient memory for DOS.
o The error "ABEND: Bad block returned via rfree" would
occur on large internetworks with a NACS installed
because the NACS would send out a shortened packet. A
normal packet can cross 8 bridges and is large enough
to hold the information that each bridge adds to it.
The short packet sent out by the NACS advertised itself
as a packet which can cross 8 bridges. However,
because it was short, the router information which
should be added to the packet was over-writing
information in memory after passing 5, or so, bridges.
This packet would get propagated throughout the
internetwork. The result was that many servers would
ABEND.
A check to make sure that the packet length was correct
has been added. If the packet length is incorrect
NetWare will discard it.
o The error "ABEND: Invalid redirection index table"
occurred after completion of a REMIRROR command on disk
drives greater than 255 MB. This error no longer will
occur as a result of large disk drives, but only when
something truly has happened to the redirection index
table.
o When a power failure occurred, UPS monitoring would
send out messages to users indicating that the file
server would be brought down. The UPS monitoring
feature then failed to down the file server. This
feature now functions as advertised.
Disk Mirroring Problems
o Disk mirroring could not be accomplished in disk drives
greater than 255 MB if the first volume size was
defined to be less than the default 255 MB value. This
was corrected.
o A mirrored disk drive failure could bring down the
entire channel under if disk mirroring was taking place
on a single Disk- Coprocessor. This is now changed to
shut down only the failed device instead of the whole
channel.
Removable Disk Drive Problems
o Enabling directory caching on a removable hard disk
drive would cause a GPI. This was fixed.
o Multiple sequences of the MOUNT and DISMOUNT commands
would eventually hang the server. The DISMOUNT command
will now free allocated memory when used.
o Multiple removable drives could not be mounted
correctly; this has been corrected.
NVER
o If NVER was run on any 8088-based workstation, that
workstation would hang. This includes IBM Model 25,
PC, PC/XT, or any other IBM PC-compatible machine.
80286-and 80386-based machines did not have this
problem. This was corrected.
FCONSOLE
o A console operator with Read, Open, and Search rights
in a given directory could not see any files from
within FCONSOLE. If the user was supervisor, or
equivalent, this problem did not appear. This was
changed.
NINSTALL
o Even parity on printers has not functioned correctly on
NetWare versions 2.1 through 2.15. The problem has
been corrected with the NINSTALL utility. Previous
versions of NINSTALL placed incorrect printer
information on the network disk when even parity was
selected.
Login Script MACHINE_NAME Variable
o If the variable MACHINE_NAME was used in the login
script and DOS 4.0 was used then the error "DOS 3.1 or
greater was required" would occur. This was corrected.
IPX.COM, NET2.COM, NET3.COM, NET4.COM
o When attempting to rename a directory through filer,
the error "file not found" would occur. This was fixed
o When attempting to rename a file that another user had
opened, the error "file not found" occurred. The error
in 2.15 rev. C will be "accessed denied."
SYSCON
o If directories were created with names up to 14
characters, as allowed by the Macintosh, those
directory names would be truncated to 8 characters when
using the DOS DIR command. This utility has been
updated to version 2.20d.
SESSION
o SESSION reported incorrect user login times. It will
now properly report this information.
NCOPY
o When copying a Macintosh file with NCOPY from one area
to another the Last Modified date was changed to the
date the file was copied. Also changed were the Last
Accessed and Date Created dates. This was seen from
the Get Info screen on the Macintosh. NCOPY will no
longer change any of those dates.
External Bridges
o The following error occurred on external bridges while
initializing LAN A: "ABEND: Cannot find the load file."
"Running Process: MUXPRC" BRIDGE.EXE was fixed.
Printing
o A printer configured for even parity did not work
properly. This feature is now properly supported.
NetBIOS
o The default number of NetBIOS sessions available was 10
(without SHELL.CFG). The default number of active
sessions was six. If more sessions were needed then an
adapter reset was required. Without the SHELL.CFG file
present, and by resetting the adapter, 10 sessions were
available. If a SHELL.CFG file was present, and it
contained the statement "NETBIOS SESSIONS=xx" where xx
was the number of NetBIOS sessions, then through the
adapter reset method, that number of sessions would be
opened. This is changed such that now the number of
NetBIOS sessions specified in the SHELL.CFG file are
immediately active without requiring an adapter reset.
o The number of local names per workstation has increased
from 16 to 26.
o The maximum number of NetBIOS session per workstation
available has increased from 100 to 250.
o The default number of sessions per workstation (without
SHELL.CFG a statement) has increased from 10 to 32.
o The minimum number of sessions and commands available
is 4 per workstation.
o A packet is now sent to the corresponding workstation
when a session is aborted. That is, the partner in a
session is now notified of the ABORT status.
o The timeout on the HANG UP command is now 20 seconds.
This includes the time used to complete pending session
sends. This places an upper bound on the time to close
a session.
o Add Name now returns the appropriate IBM error when
duplicate names are detected.
o The Session Status command no longer affects the status
of hung up or aborted sessions.
o The broadcast datagram went to the first workstation
found. The datagram would not be received by any other
member of the group. Broadcast datagrams and datagrams
to group names now get sent to every known cached
network where members of datagram groups are located.
To avoid confusion, broadcast datagrams are not
globally broadcast.
o The NetBIOS ABEND Free IPX Block Failed occurred in
situations where it should not have. There are now
only three different code paths that can cause this
ABEND; all point to legitimate causes for the error.
Disk Controller
o The disk controller selected in NETGEN labelled "IBM AT
Hard Disk Controller or Compatible" has been changed to
read "Industry Standard (ISA or AT Compatible) Disk
Controller."
LAN Drivers
o There are now two Token-Ring LAN drivers. One driver
is the standard Token-Ring driver. The second is to be
used in bridges where source routing is required.
Either driver may be used in a 16 megabit ring or a 4
Mb ring. All nodes on a ring must be configured to run
at the same speed.
The previous Token-Ring driver did not allow
applications to change the interrupt vector location in
memory. The shell would place it back at the location
where it was when the shell was loaded. The
application would hang because it expected the
interrupt vector to be elsewhere. Both of these
Token-Ring drivers will now allow an application to
relocate the interrupt vector location.
NEW ENHANCEMENTS
The following are descriptions of enhancements to SFT and
Advanced NetWare 286 v2.15 revisions A and B. Each of these
are included in the NetWare 286 2.15 rev. C release.
SHELL.CFG
o An enhancement has been added to place the IPX
configuration into the SHELL.CFG file. The user may
physically change the hardware configuration of the
NIC without running SHGEN. This can be done by placing
the statement CONFIG OPTION=n, where n is the
configuration option number.
o Interrupts 64h and 7Ah can be enabled or disabled in
the SHELL.CFG file. The statements in the SHELL.CFG
file are INT64=ON/OFF and INT7A=ON/0FF. The default
for both is ON.
o NetBIOS looks for two new parameters in the SHELL.CFG
file. These new options are:
NETBIOS INTERNET=ON/OFF (ON is the default)
NETBIOS COMMANDS=n (where n is 4 to 250. 12 is the
default)
Setting the internet flag to OFF can be advantageous if
NetBIOS is not expected to cross any bridges. The wait
time can be significantly reduced.
The number of commands needed may vary between
applications. In most cases, the default is
sufficient. However, if a NetBIOS error 22h should
occur, you may consider increasing this parameter.
Most applications will trap this error and simply retry
if a NetBIOS command is unavailable. In this case,
increasing the number of commands will improve
application performance. Anyone needing to know
specifics on this should contact the software
application developer to find out how many commands
they might require.
o Under some conditions, it is possible for a machine to
be too busy for IPX to respond to the shell. The
workstation will hang as a result. Typically, this
occurs in fast workstations (such as an IBM Model 80)
when the local hard disk is being used. The machine
will accept an IPX broadcast before a local disk
process is complete. To resolve this a retry count is
added between the shell and IPX.
Password Encryption
o Previous revisions of the 2.15 NetWare operating system
had the ability to utilize encrypted passwords on the
data bus. Now, utilities will encrypt passwords as
well. The following is a list of utilities that have
been enhanced.
ATTACH.EXE
CAPTURE.EXE
FCONSOLE.EXE
FILER.EXE
LOGIN.EXE
MAP.EXE
NPRINT.EXE
PCONSOLE.EXE
PRINTDEF.EXE
SESSION.EXE
SETPASS.EXE
SYSCON.EXE
UPS Down Parameter
o The maximum allowed time limit for UPS monitoring
systems has increased from 30 minutes to 64800 minutes
(45 days).
USERDEF
o In response to user requests, the USERDEF utility is
added to simplify the creation of groups of users with
accompanying rights and login scripts. USERDEF is a
simple front-end interface to MAKEUSER. It was
originally created for ELS NetWare, but has now been
added to SFT and Advanced NetWare so that all network
administrators will be able to make use of it.
NETGEN and BRGEN
o NETGEN and BRGEN have been changed to allow a maximum
configuration of 250 communication buffers, rather than
the 150 limit in previous versions.
MISCELLANEOUS INFORMATION
The following are descriptions of information pertaining to
NetWare 286 2.15 rev. C, but do not constitute fixes or
enhancements.
Passwords
o If you are upgrading from NetWare version 2.1, 2.11, or
2.12 and have been using the required password length
parameter, all user passwords will automatically expire
to take advantage of increased security. Users must
enter a new password to properly implement and improve
their system security.
o When your password expires, the system will ask you to
change it. If you are not attached to multiple file
servers then ignore the prompt to synchronize
passwords. Do this by pressing <ENTER> to continue.
Diskette Change
o Ignore all references to the NetWare Keyboard Lock VAP
and LAN_DRV_002 diskettes in the documentation. The
LOCK.VAP program is no longer available. Novell and
IBM drivers are contained on the LAN_DRV_001 diskette.
All other drivers are available in the NetWare
Supplemental Drivers kit.
UPS
o If you have an uninterruptable power supply (UPS)
connected to your file server, do not disconnect the
cable while the system is running. The system will
identify a disconnection as a low- battery signal and
down the file server.
(X) This information was verified by Engineering.
(X) This information was verified by Marketing.